Understanding Anatomic Pathology HL7 Messages

Conseils et astuces

Anatomic Pathology (AP) HL7 messages are structured differently than clinical chemistry or hematology HL7 messages. The first step in understanding Anatomic Pathology HL7 messages is to understand the structure of an AP case. AP cases are comprised of four distinct layers of information in a hierarchy. Each case has one or more specimens, each specimen has one or more blocks, and each block has one or more slides.

The second step in understanding AP HL7 messages is to realize that staining instruments do not produce results. Instead, instruments provide status messages which may include updates, such as a stain run has begun or a stain run has completed.

Let’s look at the components of an HL7 order message.

NOTE This order message is from a specific Laboratory Information System. Please refer to your Laboratory Information System’s driver help file for detailed information about the structure and content of the expected HL7 message.

Here is how Instrument Manager parses the specimen and test data from the order:

Here are the artifacts that are produced by this message:

Now let’s look at the components of an HL7 status message.

NOTE This status message is from a specific instrument. Please refer to your instrument’s driver help file for detailed information about the structure and content of the expected HL7 message.

Here is how Instrument Manager processes this status message with the driver configuration test code mapping:

Here are the artifacts that are produced by this message:

If you have questions about Understanding Anatomic Pathology HL7 Messages, please contact your Business Partner (if applicable) or the appropriate DI Regional Support team with your contact information, IM license number, and nature of the request.

More Tips & Tricks Articles

Conseils et astuces

TCP/IP Keep-Alive

Data Innovations’ (DI’s) Instrument Manager (IM) offers connectivity that enables integration with virtually any instrument, LIS, or EMR/EHR regardless of...

Instrument Manager, Tips & Tricks

Following Driver Updates in My DI Community

Aperçu

Data Innovations (DI) provides ways to stay up to date on the latest driver updates.The first way is right through...

Instrument Manager, Tips & Tricks

Net Gateway Startup Issues (Error 5023)

Aperçu

When IRIS and Instrument Manager (IM) are starting after a server shuts down or restarts, the .NET gateway is not...

Conseils et astuces

How to Install Instrument Manager™ Core Software

NOTE These instructions apply for Data Innovations’ North American customers. If this is your first time installing IM, please contact Data...

Conseils et astuces

How to help Data Innovations help you when requesting Support

Data Innovations' Tips & Tricks are intended to promote the effective and productive use of Instrument Manager. Fortunately, Instrument Manager...

Conseils et astuces

Evaluation Rules for Clinical Ranges Precaution

When building an Autoverification Rule Set it's common to include evaluation rules for Clinical Ranges. These rules typically set test...

Conseils et astuces

Instrument Manager System Preventative Maintenance (volume 1)

Instrument Manager is a robust software application with a proven track record of operational stability. However, as with any software...

Conseils et astuces

Instrument Manager System Preventative Maintenance (volume 2)

This month's Tips & Tricks is the second installation of Preventative Maintenance recommendations intended to help you maintain a stable...

Vous souhaitez en apprendre davantage ?